Select options
Additional equipment
-
C-DC Light tower
-
SHG-DC Additional shelves
-
SHG-SH-DC Additional shortened shelves
-
SCO-G-DC Reels adjustable rack
-
LIG-DC Shelves separation elements
-
VHM software
DC Light dry storage cabinet is a simplified version of the VIKING DC series dry storage cabinets line.
The new line of dry storage cabinets DCL consists of 3 models: DCL-6G ESD, DCL-3G ESD and DCLN-3G ESD with automatic nitrogen unit.They provide ultra-low ranges of relative humidity and quick recovery.
DCL-6G ESD series 6-sections dry storage cabinet allows handling moisture-sensitive components and materials in 6 sections. Shelves of a 6-sections cabinet can be installed in a checkerboard order, each two horizontally located sections have joint nonseparated space.
The DC Light series cabinets have the same excellent technical specifications as the main line of DC dry storage cabinets: maintaining the precise humidity level and quick dehumidification, but feature a simpler lightweight frame and fewer additional features and options.Recovery from 50% to 1% RH | 80 min |
Recovery from 50% to 5% RH | 40 min |
Average time to recover humidity to 10% RH after 10 sec door opening * | 1 min |
Average time to recover humidity to 5% RH after 10 sec door opening * | 3 min |
Average time to recover humidity to 3% RH after 10 sec door opening * | 7 min |
Average time to recover humidity to 1% RH after 10 sec door opening* | 13 min |
Average time to recover humidity to 1% RH after 20 sec door opening * | 18 min |
* - the experiment was carried out without containers inside the dry cabinet, at 50% RH relative humidity and a temperature of 25 °С
DCL-6G ESD models supplied with a grounding cord that should be connected to the ground at the breaker box after installation of the cabinet. The front panel of the Viking DC Light dry storage cabinet has a button to attach grounding strap.
DC light dry storage cabinets are only available in light gray (RAL7035).
DC light series dry storage cabinets are equipped with audible signaling of the cabinet doors opening, it works when one of the DC cabinet doors are being opened for more than 30 seconds.
Control panel with a monochrome graphic display and three control keys is located on the top front side of the cabinet.
DC light cabinets are equipped with an RS-232 port, providing the possibility to connect the cabinet with a PC and use VIKING Humidity manager software.
Additional equipment
C-DC Light tower
SHG-DC Additional shelves
SHG-SH-DC Additional shortened shelves
SCO-G-DC Reels adjustable rack
LIG-DC Shelves separation elements
VHM software
The information and/or documents contained in this website do not constitute an offer.
To learn more please fill out the form and click send.